Shower priority switch wiring diagram: Wiring Accessories for a Smarter Home. The EVlink Load Management system we always make sure that all vehicles connected can be charged while taking care of priority rights. “This new solution monitors the energy being consumed by a building’s electrical loads and then automatically distributes. Mira Advance ATL Installation & User Manual. ShoWeR PeRFoRManCe What affects shower performance? The shower's top priority is to keep the desired water temperature constant. To maintain this temperature, the shower may have to automatically change the rate of water flowing through the appliance. WIRInG DIaGRaM control board cn10 cn12.

I purchased my older home 2-years ago. We have been having some issues concerning running out of hot water.

I purchase a tester to check the elements and the thermostats. All appears to test out OK.

In the process, I read in several places online that 10-2 wiring with a double 30A breakers are needed for a heater with 4500 watt dual elements. My heater has 12-2 wiring with a double 20A breaker.So this is my question:Does having the lighter wiring create a danger? It seems that the 20A breaker should protect the 12-2 wiring from overheating. Won't the breaker 'pop' before allowing the circuit to overload? Doesn't the 20A circuit simply limit how much current is available to the water heater. It may be asking for more but it just isn't available? Hypothetically, if a person had a 1A circuit feeding an appliance rated for 30A it would never receive more that 1 amp, the breaker would immediately trip.

Currently my water heater functions without tripping the breaker. Is it a wrong assumption that it is operating within the capability of the 20A circuit?Thanks for any help,Tom. Click to expand.My current Local code requires #10 wire and 25 amp breakerA 4500 watt element draws 18.75 amps at 240 volts.

Code requires wire sized at 125% of continuous load. 18.75 x 1.25= 23.5 Amps.My previous local county building dept allowed a 30 amp breaker w/#10 wire for a 4500 element WH. My current county building dept requires #10 with the breaker to be 25 amp.Yes, the wire size in the WH interior is usually #12. That is because it was UL approved as such due to short wire lengths and type of wire used.

It doubtful that the 12 gauge wire is dropping the voltage at all. If it was you would feel heat off the wires that is feeding the water heater. Your 20 amp 220-240 volt breaker is really two 20 amp breakers in parallel. As above the maximum current draw is 18.75 amps, that is 9.375 amps per leg. Under the circuit breaker rating but you may not have a full 240 volt supply. It could be 220 volt, therefore, the current draw will be less that means lower power and less heat but you'll never notice the performance differenceTo be sure put a voltmeter in a wall outlet and measure the voltage, it be anywhere from 110 volt to 125 volt. Then place the voltmeter across the upper thermostat of the water heater.

Usually the top two connections. Here you'll read your 220 (sort of speak) voltage. Anywhere from 208 to 240 voltage will be normal.Here is a diagram Your problem is one of the heating elements is bad or the one of the two thermostat is bad. Only one heating element is on at a time and the switch over from one element to the other is done by the upper thermostat.Lastly, your hot water demand is exceeding the capacity the water heater.Here is a more detailed diagram of a water heater wiring.

A couple of pointsA 20 amp double pole breaker is actually two 20 amp single pole breakers tied together and a 30 amp double poke is two 30 amp breakers tied together. Each leg carries full current. If you put an amp-probe on one leg you will measure full current.P/E = IWatts/Voltage = Current4500/240 = 18.75 ampsI have seen 240 volt drop to 180 volt on 20 amp sole use circuit on a copier that was rated at 16 amps, once the copier was fired up. That circuit was wired with #12 but it was significant distance from breaker panel.

That distance caused the voltage drop due to the resistance of the wire at the long run.Second.The upper thermostat is the 'master' thermostat. When water in the top of the water heater gets cold it switches only one leg to the upper element. The other leg always has power.Once the upper thermostat senses that temperature setting has been reached it switches that leg to the lower thermostat.

Unit

If the upper element burns out you will get COLD water all the time since the thermostat never senses it reached temp setting.If lower element burns out or the lower thermostat remains open then you get hot water for very limited time. If the water heater asked for 'more current and it was not available' the circuit breaker would trip because of overload. The wiring INSIDE the heater had absolutely NO BEARING of the wire size to the heater. They are two completely different situations. You are operating at the limit of the wiring, but that also has NO BEARING on why you do not have sufficient hot water.

I would question HOW you tested the heater's circuitry, because, to be simplistic, it takes more than a light bulb with two wires attached to it. Our code calls for 10g copper and a 30a breaker to the WH.

Seems like too large a breaker to me. But If its a short run, the 12g and the 20a breaker obviously operates the unit.

Shower

You very likely have one element, likely the lower one burnt out. Or your switch is not sending power alternately as called for to the elements.

I have had elements that were internally missing an inch or so of themselves, but did not trip the breaker or cause any extra amp draw. Still can't figure that one out. Pretty much have to put a clamp on ammeter on the feed to the element to see if its pulling power, and use an ohmmeter to see if its shorted or intact internally. For an awfully small amount of $, one can change the switches and elements and forgo the testing if able to do so. I will venture that MANY plumbers and even electricians are hard pressed to correctly test a water heater. Much easier to just say it's 15 years old and it's gonna blow any minute now.I have a 30 gallon electric water heater, cheapest made, that I added monster anode to, and rewired to have both 4500 elements on at the same time - it heats a huge house with radiant heat. I laugh when I see these radiant guys selling flow thru 10,000 watt heaters for $1500+.

They have no place for the calcium that builds up on the elements to drop down into for later removal, and the specialized elements are 20x the cost of the dime store 4500w unit. And gas water heaters? Really, we are in the dark ages with their design and efficiency. I suppose with the 'free' natural gas now available in the USA, its not an issue for the masses.

Non priority shower unit wiring diagram chart

BTU's per $ of energy, gas almost always beats out electricity. Once you have it installed, the energy use costs easily favor gas, and usually can recoup the extra installation costs, even with the somewhat higher standby losses. The newest ones are required to be more efficient, which helps, too. You'll typically have faster recovery rates and higher first hour delivery with gas unless you've got a commercial electric WH and large elements. If you had to pay for running new gas service in, the price of energy may never recoup the savings verses using electricity, but it all depends. Right now, where available, NG is a bargain.

BTU's per $ of energy, gas almost always beats out electricity. Once you have it installed, the energy use costs easily favor gas, and usually can recoup the extra installation costs, even with the somewhat higher standby losses.

Non Priority Shower Unit Wiring Diagram System

The newest ones are required to be more efficient, which helps, too. You'll typically have faster recovery rates and higher first hour delivery with gas unless you've got a commercial electric WH and large elements. If you had to pay for running new gas service in, the price of energy may never recoup the savings verses using electricity, but it all depends. Right now, where available, NG is a bargain. Click to expand.If he is in California, his incoming water temperature is anywhere between 57 and 72 degrees (roughly). So to get a shower at 105 degrees (average shower temp), he will need anywhere between a 48 and 33 degree temp rise.

At 2 gallons per minute (standard for a shower) he will need anywhere from 14.05 and 9.66 Kilowatts to obtain that (roughly). Tom, if you click here you will find a calculator that will tell you exactly what you need to keep your shower producing the exact amount of hot water you want/need without running out.With the new DOE regulations in effect since April 16, 2015, he is going to have to replace his tank anyway and he won't be able to get the same size tank.

The new standard effectively prohibits 55 gallon or greater tank water heaters. Homeowners who want these large capacity units will have to invest double or triple in a heat pump driven design that meets DOE efficiency standards. This will also effect your wallets as these new energy efficient systems are larger (need more space, won't fit in old space). The Heatworks MODEL 1 is different. It is roughly the size of a football and meets all the new DOE requirements. It is a small tankless electric water heater with NO heating element, and, unlike any other tank or tankless unit, utilizes graphite electrodes instead.

Short explanation, no scaling or plating, no super heated part waiting to fail (or not give you as much hot water as you need), and instant, safe and INFINITE hot water. In the interest of full disclosure, I do work for the company that invented the Heatworks MODEL 1 tankless water heater, however I would love to help any of you in the forum, especially Tom, figure out your water heater needs. There is more info about the Heatworks MODEL 1 at our website found at if you click here it will take you to a page that calculates how many MODEL 1's you need for your demand and shows a ground water temp map so you can quickly figure out what you need.

Tektone SF527ES Wireless Support Module connects to an SF337C WaterproofEmergency Switch or an SF339 Pushbutton Emergency Station via a 7-pin keyedMolex connector. When properly installed, the SF527ES/SF337C assembly may belocated in a shower, bath or tub room.

The large mushrom-style button of the SF527ES/SF339 assembly is easily activated, so that calls may be placed using an elbow, shoulder,etc. Calls are cancelled by turning the button clockwise. The SF527ES has a tamperproofcase and is fully supervised, so that Tek-CARE®500 shows missing and low batteryunits. Use the IH527 Plastic Box to surface mount. To flush mount, use a plastic boxthat does not interfere with RF signals.Dimensions: 3.5'H × 1.7'W × 0.9'D (89 mm × 43 mm × 23 mm)Contact Closure: Momentary, 1.5 seconds minimumBattery: 3V Lithium (BA505), 4–5 yearsRequired: SF337C Emergency Switch for SF527.